Use this page to help identify UK electricity pylon series by D, D2, D3, S, S1, S2 and S3 line towers. Within each voltage class the tower series are arranged in approximate chronological order of introduction. See the comparisons page for other comparisons. See the series page for the list of known series.

Not all series are covered by this page; coverage is limited to available data. See the project completeness page for details.

Three and four circuit and dual voltage

The K1373 S type is three circuit (2 × 66 kV plus 1 × 33 kV).

Milliken E177 F3 (33 kV)
Rannoch-Abernethy four circuit
Spey Valley S 132/33 kV SEW
Spey Valley S 132/33 kV DEW
Spey Valley S 132/33 kV with spire
Blaw Knox K1373 S SEW
Blaw Knox K1373 S DEW

Double circuit

Double-circuit straight line towers (suspension towers) by series.

33 and 66 kV

Milliken L134 intermediate (47′–0″)
Milliken T163 D3
SEE SL3(b) D3
J L Eve C15 0.1 D3
J L Eve C15 0.1 D3 strengthened
J L Eve C15 0.1 D3 semi-strengthened
J L Eve C15 0.15 D3
Milliken E177 D3
Milliken K721 D
Blaw Knox K1373 A SEW †
Blaw Knox K1373 A DEW
Blaw Knox K1373 A special DEW †
Blaw Knox K1373 A (85° EW swing) †
Blaw Knox K4611 DA SEW
Blaw Knox K4611 DA DEW
NWE SL7 D3
SEE SL6 line
SEE SL8 D3
NWE SL4 D3
J L Eve C333 D3
Abergavenny/Cwmbran D3
Preston D3 (RPA)
Preston D3 (RPB)
Preston DD3 (RPB)
Preston unknown suspension
Unidentified D3
Blaw Knox K9906 D3
L4(m) 66 D3

† Confirmed uprated to 132 kV

132 kV

Note that some K1373/K4611-type lines—whose towers are depicted above—have been uprated for 132 kV.

CS PL1 D2
SEE PL2 D2
EE PL1 D2
SWE PL1 D2
SEE PL1a
SEE PL1(b) D2
Tummel–Abernethy “S”
Spey Valley S 132/132 kV
Spey Valley S 132/132 kV with spire
CE PL3 D2 SEW
CE PL3 D2 DEW
PL4/WGR D2
PL4/WGR DD2
NWE PL10 D2, retrofit peak
Lydney DD2 E20?
SEE PL7 D2
SEE PL7 DD2
Blaw Knox K5735 DD2
SWE PL16 D2
SWE PL16 DD2
“Scottish” PL16 D2S
PL16 D2S (strengthened)
“Scottish” PL16 DD2S
Eve C670 D2
Eve C670 D2 (uplift)
Eve C670 D2 (strengthened)
Eve C670 DD2
Eve C534 D2
Eve C772 D2
Blaw Knox T1498 D2L
L7(c) D
L7(c) D double earthwire
Eve C1415 D2
Quoich–Broadford D2L
Quoich–Broadford D2L (SEC)
L4(m) D

The Milliken PL1 10° suspension towers are often used as straight line towers than angle towers, fitted with vertical insulators:

SS PL1 S10 as S
SWE PL1 D10 as D

275 kV

Note that L2 towers were designed for 275 and 380 (or 400) kV and are listed under 400 kV below.

L66 D2 STD
Blaw Knox L3 D
Blaw Knox L3 D (modified peak)
J L Eve L3 D (C673)
Blaw Knox T1521 D
J L Eve L3 D (C864)
Blaw Knox T2175 D
Blaw Knox L3/L3(c) DS
L8 RD STD (275 kV)
L8 RD M4.9 (275 kV)

400 kV

L2 D
Blaw Knox T1648 D
Balfour Beatty L6 D
BICC L6 D
Dungeness “headless” L6 BICC D30 M20′
Blaw Knox L6 D
J L Eve L6 D
L2 D DMC
L6(c) D
L6m D
L8(c) D
L9 LD
L12 D
L12 LD
L13 D
L13 LD
SSE400 D/DL
SSE400 D (lower strength)
AS4 AD/BD

Single circuit

Single-circuit straight line towers (suspension towers) by series.

33 and 66 kV

Milliken E102 S3
[Marshall] S3
Milliken E177 S3
Blaw Knox K4611? SA? SEW
Blaw Knox K4611? SA? DEW
Riley and Neate H99 line mast, with EW
Riley and Neate H99 line mast, no EW

132 kV

CS PL1 S2
CE PL1 S2
SS PL1 S2
SWE PL1 S2
SEE PL1a S2
SEE PL1(b) S2
Stafford–Wolverhampton S2 (see SS PL1)
CE PL3 S2 SEW
CE PL3 S2 DEW
PL4/WGR S2 SEW
PL4/WGR S2 DEW
Blaw Knox K1201 S2
Blaw Knox K1201 S2 (strengthened)
Blaw Knox K1201 SS2
Blaw Knox K1420 S2
Riley and Neate H99 132 kV uprated mast

The following types have been observed but no documentation has been recovered and the designations are for convenience only:

L4(m) S (A)
L4(m) S (B)

275 kV

L34 S1
Coylton–Auchencrosh line tower

400 kV

L8(c) Modified S
C-IVI-1 intermediate