Jump to page content

KBK update for Sunday, 10th March

Re-inspection of the Hirose M83S, M83A, MD and MJ series datasheet shows that the force figures are not indicating the permissible manufacturing range, but in fact the tolerance (as recently determined for US M4/M5/M6). The Cherry common schema page along with the MD and MJ schema pages are updated accordingly. The range for MD, 50〜80 gf, comes out at 65±15 gf, and 65 g is what the Epson PX-8 Technical Manual gives for its standard weight MD switches.

View within the updates for 2019

Comments

None yet.

Add comment

Name:
E-mail:
Website:
Caption:
Comment:

Plain text only; for hyperlinks use the form “[URL caption]”.

This site is about: